A volumetric feeder meters material by volume, usually with a screw or disc set to a calibrated rate. A gravimetric feeder uses weight measurement to monitor or control the amount delivered. Volumetric feeding can suit a stable material and a process with room for manual checks; gravimetric feedback is worth considering when changes in bulk density or documented mass flow matter. Neither label guarantees a result without an appropriate setup and verification.
Compare the control method
| Question | Volumetric feeder | Gravimetric feeder |
|---|---|---|
| Measurement basis | Volume delivered at a set operating rate | Weight measured over time or per dose |
| Setup | Calibrate against a weighed sample | Configure and calibrate the weighing and control system |
| Bulk-density changes | Mass delivered can change at the same setting | Weight feedback can help compensate, within system limits |
| Practical checks | Repeat sample checks as material or settings change | Check weighing, refill behaviour and calibration |
| Selection concern | Frequency of adjustment and acceptable variation | Integration, maintenance and performance at the required rate |
Conair’s feeder explanation describes timed sample catches for setting a volumetric feeder and a loss-in-weight feeder using a load cell. Those examples explain the distinction; they do not establish performance for your material or plant.
What changes the decision?
A free-flowing, consistent additive used at a steady rate may be a practical volumetric application if periodic checks show the process meets its tolerance. If the material’s bulk density changes between lots, the same screw setting can deliver a different mass. A gravimetric system can observe weight change and adjust delivery, but bridging, vibration, refill periods and poor calibration still deserve attention.
Specify the tolerance you need at the actual minimum and maximum feed rates, along with how it will be measured and over what interval. Ask for a trial with the real material. A high catalogue capacity does not demonstrate performance at a very low additive rate, and an accuracy figure without its test conditions is hard to compare.
For a loss-in-weight feeder, plan a discharge test through refill and recovery before accepting an accuracy claim.
Look at the complete arrangement
A feeder meters an ingredient; a blender combines components. Some equipment performs both functions, but buying a gravimetric feeder does not automatically provide a complete batch blender. Confirm whether the quote covers one additive, multiple components, mixing, controls and connection to the processing machine.
For a concrete comparison, motan’s MINICOLOR V brochure lists the V as volumetric and the G as loss-in-weight gravimetric additive dosing. It also lists separate batch dosing and mixing units. motan’s MINICOLOR G page describes its load-cell dosing module. These are examples of configurations, not proof of a particular accuracy in your application.
Browse dosing and mixing companies and the motan profile when preparing a shortlist.
Questions to send with an enquiry
- What ingredients, particle forms, bulk densities and flow issues are expected?
- What are the required feed rates, tolerance and sampling interval, including startup and refill?
- Is the duty continuous or synchronized with a machine cycle? What signal and mounting space are available?
- What calibration, cleaning, changeover and maintenance steps are required?
- Can the supplier demonstrate the proposed arrangement using your material and measurement method?
Ask for the feeder’s limitations as well as its nominal range. The right choice is the one that meets your process requirement under agreed test conditions.
For batch blending with regrind, use usable batch mass and cycle time to size a blender.