Loss-in-Weight Feeder Refill Accuracy: What to Measure

Updated

A loss-in-weight feeder can meet its total mass target while delivering too much or too little during refill. To assess that interval, compare independently measured discharge over agreed time windows with the controller’s reported rate, and mark when refill starts, ends and normal weighing resumes.

What changes during refill?

Between refills, the controller estimates discharge from the loss of weight over time and adjusts the feeding device toward its setpoint. When material enters the hopper, the scale sees incoming material as well as outgoing material. The resulting weight change alone no longer reveals the discharge rate. Coperion’s feeder controls description explains this limitation.

Controllers handle the interval differently. A controller may run the discharge device using a speed derived from previous operation until a usable weight-loss signal returns; another may use a different refill strategy or additional controls. Ask the supplier exactly what the proposed controller does during refill, how it detects the end of refill and when it returns to weight-based control. A displayed rate during that interval may be an estimate rather than an independent measurement of discharge.

A total can hide a short disturbance

Suppose the target is 60 kg/h for three consecutive one-minute periods: 1.00 kg per period. An illustrative measured sequence of 1.00, 1.12 and 0.88 kg totals 3.00 kg, exactly the three-minute target. Yet the second and third periods deviate by +12% and −12%. These numbers illustrate the arithmetic, not a claim about a particular feeder.

For a nonzero target mass, calculate each window’s relative error as (measured mass − target mass) ÷ target mass × 100%. Compare that measured mass with the controller rate averaged over the same window, or integrate the controller rate over that window to compare masses; an instantaneous rate sample is not equivalent.

A three-minute total answers a different question from a one-minute result. Choose the window according to the downstream process and agree whether the acceptance limit applies to each window, a statistical measure across windows, the full test total, or a combination. State how partial windows at refill boundaries are treated. A quoted accuracy without its test duration, calculation and material conditions is difficult to compare.

Plan a test around the refill cycle

With the supplier, arrange safe collection or independent measurement of actual discharge without defeating guards or disturbing the weighing system. Coperion’s guidance on scale accuracy discusses consecutive samples at the feeder output. Include several refill cycles and normal operation between them; agree the number and duration before the test.

Record together Why it matters
Timestamped independent discharge mass for each agreed interval Shows what actually left the feeder, including short deviations
Setpoint and controller-reported rate over matching intervals Allows comparison with the target and what the controller indicated
Refill start and end, and return to weight-based control Locates deviations in refill and recovery rather than averaging them away
Material grade, condition, bulk behaviour and feed rate Makes results meaningful for the material and operating range tested
Refill settings, hopper levels, upstream supply and downstream conditions Identifies the setup under which the result was obtained
Measurement method, calibration, window and acceptance calculation Makes the result repeatable and comparable between proposals

Agree on the test material, minimum and maximum relevant rates, pass limits and how missed or incomplete samples will be handled. Record changes to settings and repeat the agreed test after an adjustment. A result for one material or rate does not establish performance for every other one.

Investigate the pattern before changing settings

A deviation around refill is an observation, not a diagnosis. Check whether it aligns with the refill event, recovery or another disturbance. Possible causes include material flow changes, leakage through the refill device after it closes, vibration affecting the weight signal, or pressure differences at the hopper or discharge. Coperion’s troubleshooting guidance describes these kinds of influences and checks. Use the supplier’s procedure to isolate the cause; do not assume a fixed refill rate or a universal controller correction will solve it.

If measurement method itself is still under consideration, see gravimetric vs volumetric feeders. For the wider equipment request, use the RFQ checklist.