Gravimetric Batch Blender Sizing for Plastic Regrind

Updated

Size a gravimetric batch blender for the usable blend it can produce repeatedly with your actual recipe and regrind—not simply its advertised weight per batch. Compare completed, acceptable batches per hour with the press’s sustained and peak draw, then check whether the smallest ingredient can be dosed within your tolerance.

Batch blenders weigh components, mix them and discharge the blend; the sequence and available configurations vary by machine. Shini describes its gravimetric blender process, while Maguire’s blender brochure shows different configurations, including options for low-density material. Ask suppliers which configuration and material assumptions support their quoted capacity.

Convert a complete cycle to hourly output

For a stable, repeated cycle, use usable mass per acceptable batch × 3,600 ÷ complete cycle time in seconds. The cycle must include the dosing, weighing, mixing and discharge time needed before the next usable batch is available. Rejects and interruptions cannot be counted as good output.

For illustration, suppose both proposals produce a 1.8 kg acceptable batch with the same recipe and material. The numbers below are hypothetical; they are not equipment ratings.

Complete cycle Calculated output Against 120 kg/h sustained demand
42 seconds About 154.3 kg/h Above demand under the stated stable conditions
60 seconds 108 kg/h Below demand under the stated stable conditions

The first calculation leaves theoretical margin, but it does not prove the machine can sustain the duty on your floor. Check whether the trial includes replenishment delays, actual regrind behavior and any interruptions. A supplier’s maximum throughput may depend on its configuration: an older Conair blender manual associates maximum throughput with particular valve arrangements. Do not transfer that rating to a different machine or recipe.

Check the smallest dose and the buffer

In the same hypothetical 1.8 kg batch, an ingredient specified as 1% of the total blend is 18 g. Confirm that the controller defines the percentage on that basis, then ask for the achievable dose and tolerance at that quantity with the actual material. A blender that meets total throughput still needs to meet the agreed recipe tolerance; a displayed setpoint alone is not evidence of the delivered mix.

Provide the press’s peak draw, its duration and startup sequence. Identify usable inventory in any downstream buffer, the initial fill and refill delay. A buffer may cover a short draw above the blender’s output, but it cannot indefinitely make up a sustained shortfall. Ask the supplier to show the proposed inventory balance for your schedule, including startup and recovery after a pause.

Regrind can vary in particle shape, fines and bulk density. Describe the range, loading method and expected low hopper level, and supply representative material for the test. If it does not feed consistently, discuss conditioning or screening, a different dosing arrangement, or a blended buffer with the supplier. Establish the effect on the recipe and production schedule before choosing a remedy.

Put the same trial in both quote requests

Ask each supplier to state usable batch mass, complete cycle time, sustained good output, smallest dose and recipe tolerance for your materials. Request the configuration, test method and exclusions in writing. Agree in advance on pass limits, sample collection, measurement method, duration and how rejects and interruptions count.

Run representative virgin resin and regrind through startup and sustained production at the agreed demand. Include low material levels and restart, and record bridging, starvation, refill delays, good batch output and measured composition. For the whole trial, divide the accepted blend mass by elapsed time, including rejects, interruptions and refills within the agreed test scope. Compare this measured rate with demand separately from the illustrative cycle calculation. Both output and composition must meet the agreed limits for the proposed setup to pass; a test using only easy-flowing pellets does not resolve the regrind question.

If the metering principle is still undecided, compare gravimetric and volumetric feeders. Browse Maguire and use the RFQ checklist to give vendors the same requirements.

Sources

Related categories

Related companies