Compare granulator trials by weighing all output from a timed run and, where your quality procedure permits, the portion that actually meets your regrind specification. A faster gross rate can deliver less conforming material. Use the same scrap, clock rules and acceptance checks for both suppliers, then validate each regrind in your own process before releasing it for production.
Set up a fair trial
Divide a representative batch of clean injection-molding sprues between the two suppliers. Record the resin and additives, piece dimensions, feed weight and any preparation. Agree on the target particle distribution, fines limit and test method with your quality team before either run. Give both suppliers the same requirements and record the proposed machine, screen, knife condition, feed and discharge arrangements.
Agree when the clock starts and stops. Include routine stoppages such as clearing a normal feed interruption in the elapsed time for both machines; record their duration and cause. Document any exceptional interruption separately and decide together whether a repeat is needed. Weigh and identify the complete output from each run, including fines collected by the agreed method. Record material left in the machine or collection system so that unexplained losses can be investigated.
Screen selection affects the trade-off between throughput and regrind characteristics. Cumberland describes that relationship; Wittmann’s discussion of scrap testing also describes separating particle-size fractions and notes that actual throughput depends on the material and handling conditions. Record the screen used rather than assuming identical settings will suit both machines.
Calculate gross and conforming output
The following numbers are hypothetical. Each run lasted 30 minutes, including routine stoppages. The complete output was segregated and reweighed under an agreed, approved classification procedure after the timed machine runs. Both portions labeled conforming met the stated regrind specification; the remainder did not. These rates compare machine-run time only. If classification is required in normal production, record its time and cost for each supplier and include them consistently in the production-rate and cost comparison; the table alone does not provide that comparison.
| Measure | Supplier A | Supplier B |
|---|---|---|
| Total output | 60 kg | 54 kg |
| Conforming output | 45 kg | 49 kg |
| Gross rate | 120 kg/h | 108 kg/h |
| Conforming rate | 90 kg/h | 98 kg/h |
Rate equals measured weight divided by elapsed hours. A has the higher gross rate, but B has the higher measured conforming rate. This comparison is useful only for the agreed feed, settings and classification procedure. It does not establish a guaranteed continuous rate or show that either regrind is ready for production.
Do not assign a whole batch an accepted weight by multiplying its total by the result from one arbitrary grab sample. If only samples were tested, report sample results as such and agree on a representative sampling plan with your quality team before making a batch-level estimate. Do not credit a supplier for sorting rejected material unless sorting is an approved, normal part of the intended process and its time, losses and cost are included. If the batch fails and no approved separation route exists, hold it for a quality decision.
Keep the press trial separate
For each supplier’s regrind, agree on the blend ratio, molding conditions, relevant part checks and acceptance limits. A particle test alone does not establish that the material will perform in the part; a successful press trial likewise does not replace the agreed batch disposition. Record the result and decision for each material separately.
Ask each supplier for a trial report with the feed and output weights, elapsed time and stoppages, settings, classification results and any proposed changes. If the results are incomplete, request a repeat under the shared protocol before comparing quotes.
For the equipment choice itself, see granulator vs shredder and beside-the-press vs central granulators. Use the RFQ checklist to send the trial conditions with your request. Browse the Wittmann and Hellweg profiles as starting points, not recommendations for a particular trial.