Chillers vs Mould Temperature Control Units (TCUs) for Plastics

Updated

A chiller removes heat from a process fluid and supplies cooling. A mould temperature control unit (TCU) circulates fluid to bring a mould to its operating temperature and maintain it, using heating and cooling as needed. They can serve different parts of the same process, and some equipment combines their functions.

Compare the jobs

Question Industrial chiller Mould temperature control unit
Main job Supply cooling to a process or circuit Bring the mould circuit to a target temperature and maintain it
Heating Not the defining function May be needed at start-up or during interruptions
Control focus Cooling supply and heat removal Temperature of the circulating medium or mould
Selection inputs Cooling load and required supply conditions Temperature, fluid, heating, cooling and pump capacity
Relationship Can supply cooling to a compatible system May need a separate cooling supply, depending on design

These are functional distinctions, not a promise that every product has the same arrangement. Check the proposed circuit and operating limits with the supplier.

How temperature control works

In injection moulding, hot material repeatedly adds heat to the mould. A circulating medium carries heat through mould channels. The TCU can heat the mould before production and remove heat when needed to maintain the operating condition. Regloplas explains the mould circuit and its selection factors.

The temperature displayed at the unit is not automatically the temperature at every point in the mould. Channel design, flow and measurement location matter. Ask where the proposed system measures temperature and how its performance will be checked on your mould.

When both functions are needed

A plant may need chilled fluid for cooling and a separate TCU to manage the mould circuit. Whether they are connected depends on the equipment and the available cooling supply. A TCU’s cooling capacity also depends on its set point; compare capacity at actual operating conditions, not just a headline rating. Regloplas lists temperature, medium, heating and cooling capacity, pump flow and pressure among its specifications.

Integrated equipment is another possibility. Frigel describes its Microgel RSY as a water-cooled chiller with two independent temperature-control zones. That is a specific configuration, not a description of every chiller or TCU. Ask for a circuit diagram and the utilities required at your site.

If you have chosen a chiller and have loop readings, use flow and temperature rise to estimate its cooling load.

Questions to take to a supplier

  • What mould and process temperatures are required, and where must they be measured?
  • What cooling load, flow and pressure are required at those conditions? Are there separate zones?
  • What fluid and cooling supply are available, and are they compatible with the proposed equipment?
  • What heat-up time, operating schedule and variation in production load should the proposal cover?
  • What controls, connections, commissioning and local service are included?

Browse process cooling and temperature control companies, including Frigel and REGLOPLAS. Use the RFQ checklist to give suppliers the same operating conditions for comparison.

If you have chosen a TCU, compare water and oil controllers at the same mold duty.

Sources

Related categories

Related companies

Related guides